{"product_id":"fc-apc-fc-apc-sm-simplex-fiber-patch-cable","title":"FC\/APC-FC\/APC SM Simplex Fiber Patch Cable","description":"\u003cdiv class=\"product-description-wrapper\" style=\"font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Helvetica, Arial, sans-serif; color: #333333; line-height: 1.6; font-size: 15px;\"\u003e\n    \n    \u003cp\u003eHigh-bandwidth telecommunication networks, analog RF video distribution loops, and sensitive laser-based optical systems demand extreme precision and minimal signal reflection. The \u003cstrong\u003eFC\/APC-FC\/APC SM Simplex Fiber Patch Cable\u003c\/strong\u003e is a professional-grade singlemode optical jumper engineered to deliver low insertion loss while drastically minimizing back reflections. Featuring threaded metal FC barrels on both ends mated to an 8-degree angled physical contact (APC) ceramic ferrule polish, this simplex patch cord provides secure, vibration-resistant connectivity for high-stakes optical transmission networks.\u003c\/p\u003e\n    \n    \u003cp\u003eDesigned for long-haul telecommunication backbones, CATV (Cable Television) systems, FTTx distribution frames, and precise laboratory testing equipment, this heavy-duty simplex assembly ensures long-term signal stability and protects sensitive laser transmitters from the performance degradation caused by reflected light.\u003c\/p\u003e\n\n    \u003ch3 style=\"font-size: 20px; color: #111111; margin-top: 25px; margin-bottom: 12px; border-bottom: 1px solid #e5e5e5; padding-bottom: 6px;\"\u003ePrecision Threaded FC Architecture and APC Polish Advantage\u003c\/h3\u003e\n    \u003cp\u003eUnlike standard push-pull connectors, the FC (Ferrule Connector) interface relies on a robust threaded metal coupling nut and keyway alignment structure. When screwed securely into a matching bulkhead adapter, this mechanical design completely eliminates rotational movement and axial displacement, making it ideal for environments subject to mechanical vibrations or thermal fluctuations.\u003c\/p\u003e\n    \n    \u003cp\u003eThe hallmark of this assembly is its 8-degree APC polish angle. By cutting the ceramic ferrule tip at an 8-degree angle, any reflected light escaping the glass core is redirected out into the cladding layer rather than bouncing straight back into the laser transmitter source. This specialized geometric polish achieves exceptional return loss metrics (typically ≥ 60dB), making APC patch cords essential for high-power analog video transmission and dense WDM (Wavelength Division Multiplexing) architectures. For engineers, installers, and telecom contractors requiring professional fusion splicing systems, optical cleaning tools, or distribution racks, explore our primary warehouse inventory in the \u003ca href=\"https:\/\/superflash.ae\/collections\/fiber-optic-cables\" target=\"_blank\" style=\"color: #0066cc; text-decoration: underline;\"\u003efiber optic cables catalog\u003c\/a\u003e.\u003c\/p\u003e\n\n    \u003ch3 style=\"font-size: 20px; color: #111111; margin-top: 25px; margin-bottom: 12px; border-bottom: 1px solid #e5e5e5; padding-bottom: 6px;\"\u003eSingle-Mode Optical Integrity and Rugged Jacket Construction\u003c\/h3\u003e\n    \u003cp\u003eAt the center of this simplex cable is high-purity singlemode OS2 (9\/125µm) optical glass optimized for 1310nm and 1550nm transmission windows. Built with bend-insensitive fiber formulations, the cable maintains low attenuation even when routed through tight enclosures or complex cable management trays. The internal glass strand is protected by a flame-retardant, low-smoke zero-halogen (LSZH) outer jacket that prevents toxic fumes in enclosed spaces while safeguarding the delicate core against pulling tension during installation.\u003c\/p\u003e\n    \n    \u003cp\u003eEvery connector assembly undergoes rigorous optical testing to verify ultra-low insertion loss (typical ≤ 0.25dB) and high return loss, ensuring seamless integration into existing infrastructure. For technical teams expanding regional distribution networks or configuring complex patch panels, review our advanced optical management frameworks.\u003c\/p\u003e\n\n    \u003ch3 style=\"font-size: 20px; color: #111111; margin-top: 25px; margin-bottom: 15px; border-bottom: 1px solid #e5e5e5; padding-bottom: 6px;\"\u003eKey Technical Specifications\u003c\/h3\u003e\n    \u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 25px; font-size: 14px;\"\u003e\n        \u003ctbody\u003e\n            \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n                \u003ctd style=\"padding: 10px; border: 1px solid #e5e5e5; font-weight: bold; width: 35%;\"\u003eCable Assembly Type\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px; border: 1px solid #e5e5e5;\"\u003eFC\/APC to FC\/APC Singlemode Simplex Fiber Patch Cable\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 10px; border: 1px solid #e5e5e5; font-weight: bold;\"\u003eFiber Core Specifications\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px; border: 1px solid #e5e5e5;\"\u003eSinglemode OS2 9\/125µm (G.652.D \/ G.657.A1 Compatible)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n                \u003ctd style=\"padding: 10px; border: 1px solid #e5e5e5; font-weight: bold;\"\u003eConnector Interface\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px; border: 1px solid #e5e5e5;\"\u003eFC Threaded Metal Barrel with 8-Degree APC Ceramic Ferrule\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 10px; border: 1px solid #e5e5e5; font-weight: bold;\"\u003eInsertion Loss Performance\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px; border: 1px solid #e5e5e5;\"\u003e≤ 0.25dB Maximum Across Standard Wavelengths\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n                \u003ctd style=\"padding: 10px; border: 1px solid #e5e5e5; font-weight: bold;\"\u003eReturn Loss Metrics\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px; border: 1px solid #e5e5e5;\"\u003e≥ 60dB (Angled Physical Contact Grade)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 10px; border: 1px solid #e5e5e5; font-weight: bold;\"\u003eCoupling Mechanism\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px; border: 1px solid #e5e5e5;\"\u003eThreaded Metal Screw Nut with Keyway Alignment\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n                \u003ctd style=\"padding: 10px; border: 1px solid #e5e5e5; font-weight: bold;\"\u003eJacket Material Standard\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px; border: 1px solid #e5e5e5;\"\u003eLSZH (Low Smoke Zero Halogen) Outer Sheath (Yellow\/Green)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 10px; border: 1px solid #e5e5e5; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px; border: 1px solid #e5e5e5;\"\u003e-20°C to +75°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n\n    \u003ch3 style=\"font-size: 20px; color: #111111; margin-top: 25px; margin-bottom: 12px; border-bottom: 1px solid #e5e5e5; padding-bottom: 6px;\"\u003eInstallation and Handling Best Practices\u003c\/h3\u003e\n    \u003col style=\"padding-left: 20px; margin-bottom: 25px;\"\u003e\n        \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAlign the Keyway Carefully:\u003c\/strong\u003e When attaching the FC connector, ensure the alignment key on the ferrule matches the slot inside the bulkhead adapter before tightening the metal screw nut to prevent tip damage.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMaintain Strict End-Face Cleanliness:\u003c\/strong\u003e APC polished surfaces are extremely sensitive to dust particles. Always clean the ferrule tip with a specialized click-cleaner prior to mating to preserve the high return loss metrics.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eNever Mix APC and UPC Connectors:\u003c\/strong\u003e Mating an APC connector directly to a UPC (blue) connector will cause physical damage to the angled ceramic tips and create severe insertion loss. Always verify adapter types.\u003c\/li\u003e\n    \u003c\/ol\u003e\n\n    \u003ch3 style=\"font-size: 20px; color: #111111; margin-top: 25px; margin-bottom: 12px; border-bottom: 1px solid #e5e5e5; padding-bottom: 6px;\"\u003eRelated Fiber Optic Assets \u0026amp; Collections\u003c\/h3\u003e\n    \u003cp\u003eTo scale out your full architectural network setup or cross-compare with other high-precision termination variants, please explore our alternative setups and hardware solutions below:\u003c\/p\u003e\n    \u003cul style=\"padding-left: 20px; margin-bottom: 25px;\"\u003e\n        \u003cli style=\"margin-bottom: 8px;\"\u003e\u003ca href=\"https:\/\/superflash.ae\/products\/lc-fiber-optic-loopback-cable\" target=\"_blank\" style=\"color: #0066cc; text-decoration: none; font-weight: bold;\"\u003eExplore LC Fiber Optic Loopback Cable Specifications\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli style=\"margin-bottom: 8px;\"\u003e\u003ca href=\"https:\/\/superflash.ae\/products\/ftta-outdoor-weatherproof-fiber-optic-patch-cable\" target=\"_blank\" style=\"color: #0066cc; text-decoration: none; font-weight: bold;\"\u003eView FTTA Outdoor Weatherproof Fiber Patch Cables\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli style=\"margin-bottom: 8px;\"\u003e\u003ca href=\"https:\/\/superflash.ae\/products\/4-core-lc-upc-to-lc-upc-singlemode-9-125%C2%B5m-armored-fiber-optic-patch-cable\" target=\"_blank\" style=\"color: #0066cc; text-decoration: none; font-weight: bold;\"\u003eCheck 4-Core Singlemode Armored Fiber Patch Cables\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli style=\"margin-bottom: 8px;\"\u003e\u003ca href=\"https:\/\/superflash.ae\/products\/sc-apc-sc-apc-single-mode-duplex-fiber-optic-patch-cord\" target=\"_blank\" style=\"color: #0066cc; text-decoration: none; font-weight: bold;\"\u003eShop SC\/APC to SC\/APC Single-Mode Duplex Patch Cords\u003c\/a\u003e\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003ch3 style=\"font-size: 20px; color: #111111; margin-top: 25px; margin-bottom: 12px; border-bottom: 1px solid #e5e5e5; padding-bottom: 6px;\"\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n    \n    \u003cdiv style=\"margin-bottom: 15px;\"\u003e\n        \u003cp style=\"font-weight: bold; margin-bottom: 4px; color: #111111;\"\u003eQ: What is the main advantage of an APC polish compared to a standard UPC polish?\u003c\/p\u003e\n        \u003cp style=\"margin-top: 0; margin-bottom: 10px;\"\u003eA: An APC (Angled Physical Contact) polish cuts the ferrule end-face at an 8-degree angle, reflecting stray light out into the cladding instead of back toward the laser source. This yields exceptional return loss (≥ 60dB), protecting sensitive lasers from back-reflection noise.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \n    \u003cdiv style=\"margin-bottom: 15px;\"\u003e\n        \u003cp style=\"font-weight: bold; margin-bottom: 4px; color: #111111;\"\u003eQ: Why does this patch cable use FC threaded connectors?\u003c\/p\u003e\n        \u003cp style=\"margin-top: 0; margin-bottom: 10px;\"\u003eA: The FC connector features a threaded metal screw barrel that locks securely into place, offering superior mechanical stability and vibration resistance compared to standard push-pull latches.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \n    \u003cdiv style=\"margin-bottom: 15px;\"\u003e\n        \u003cp style=\"font-weight: bold; margin-bottom: 4px; color: #111111;\"\u003eQ: Can I connect this FC\/APC patch cable into an FC\/UPC blue adapter?\u003c\/p\u003e\n        \u003cp style=\"margin-top: 0; margin-bottom: 10px;\"\u003eA: No, mixing APC (green) and UPC (blue) connectors results in physical air gaps, high insertion loss, and potential scratching of the ceramic tips. Always connect APC to matching green APC adapters.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"SUPER FLASH","offers":[{"title":"Default Title","offer_id":49033114517760,"sku":null,"price":0.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/1888\/2304\/files\/FCAPCtoFCAPCSinglemodeSimplexPatchCableOverview.png?v=1784545182","url":"https:\/\/superflash.ae\/products\/fc-apc-fc-apc-sm-simplex-fiber-patch-cable","provider":"Super Flash General Trading LLC","version":"1.0","type":"link"}